TECHNICAL SPECIFICATION OF FIELD TELEPHONE CABLE

Ser

Description

Technical Specification

1

Nomenclature

Field Telephone Cable

2

Make and Model

Yilaite Army wire

3

Country of Origin

China

4

Country of Manufacture

China

5

Country of assembly

China

6

Year of Manufacture

2011

7

Apparent Shape

Double wire(Twisted)

8

Color

Black

9

Warranty

Minimum 01 (One)year after

final acceptance of all item

10

Conductors Physical characteristics

a.. Number of Strands

07 Nos

 

b.. Number of Tin covered copper Strands 

04 Nos

 

c.. Number of Zinc covered steel Strands 

03 Nos

 

d.. Diameter of each Strands 

0.28 mm +/-  0.01 mm

 

11

Thickness of insulation (Polyethylene) 

l\ilinimum 0.35 mm

12

Thickness of Polyamide Jacket (Nylon) 

0.15 mm (Average)

 

13

Overall diameter of single conductor 

Maximum 2.30 mm

14

Breaking load for two wires conductor 

Minimum 72 Kg

15

Cutting load test 

55 lbs (Average)/ 25 Kg

(Averaqe)

16

DC Loop Resistance 

151 Ohm/ Km (at 20"C)

17

lnsulation Resistance 

2000 M Ohm/ Km (Minimum)

18

Dielectric Strength Test 

1000 V AC (Minimum)

19

Weight of Zinc Cover for each steel strand

Minimum 25 gm/ Kg

 

20

Weight of Tin Covered for each copper strands

8.75-24.8 gm/kg

21

No of Twist/m

14-16 Nos(Average)

22

Abrasion Test

The cable can withstand the abrasion if an empty 03 ton vehicle runs over the cable for 08-10 times on natural ground

23

Environmental Standard

a.. Operating Temparature

-5 Deg to +55 Deg C

b..Storage Temparature

-5 Deg to +55 Deg C

c.. Humidity Permissible Condition for Operation

Maximum 95%

 